These pour-in loops are made of polypropylene wire can only be used 1-mail. After installation, the loop protruding from the concrete is ground off. This ensures that there is no rust formation afterwards.
During casting the label must remain visible from the concrete, because it contains the weight class-lot number-manufacturer. The loop must always be attached to the reinforcement, because it is part of the total construction.
CIL-PP | Permissible load (kg) (*) | Minimum reinforcement mesh mm²/m | Length L of reinforcement mm | Height H of reinforcement cm | Dimensions (mm)h | Loop diam | |
---|---|---|---|---|---|---|---|
CIL-PP-0150 | 150 | Q131 | 450 | 300 | 6 | 200 | |
CIL-PP-0250 | 250 | Q131 | 500 | 350 | 8 | 225 | |
CIL-PP-0360 | 360 | Q131 | 550 | 350 | 10 | 235 | |
CIL-PP-0500 | 500 | Q188 | 650 | 450 | 12 | 255 | |
CIL-PP-0850 | 850 | Q188 | 700 | 500 | 14 | 285 |
(*) Ensure that all load factors have been taken into account.
Safe working loads at concrete strength of >15 N/mm²
The specified steel wire diameter is only an indication and may vary depending on the loop construction.